Table 3-10. Recommended Operating Conditions (continued)
PARAMETER
MIN NOM MAX UNIT
SUPPLY NAME DESCRIPTION
Voltage range for the USB ID
USB0_ID 1.710 1.800 1.890 V
input
Voltage range for the USB ID
USB1_ID
(6)
1.710 1.800 1.890 V
input
Commercial Temperature 0 90
Operating Temperature
Industrial Temperature -40 90 °C
Range, T
j
Extended Temperature -40 105
(1) The supply voltage defined by OPP100 should be applied to this power domain before the device is released from reset.
(2) Not available on the ZCE package. VDD_MPU is merged with VDD_CORE on the ZCE package.
(3) This supply is sourced from an internal LDO when RTC_KALDO_ENn is low. If RTC_KALDO_ENn is high, this supply must be sourced
from an external power supply.
(4) VDDS should be supplied irrespective of 1.8-V or 3.3-V mode of operation of the dual-voltage IOs.
(5) For more details on power supply requirements, see Section 4.1.4.
(6) Not available on the ZCE package.