Datasheet
www.ti.com
DISSIPATION RATINGS
RECOMMENDED OPERATING CONDITIONS
ELECTRICAL CHARACTERISTICS
AM26LS32AC , , AM26LS32AI , , AM26LS33AC
AM26LS32AM , AM26LS33AM
QUADRUPLE DIFFERENTIAL LINE RECEIVERS
SLLS115E – OCTOBER 1980 – REVISED OCTOBER 2007
DERATION
T
A
≤ 25 ° C T
A
= 70 ° C T
A
= 125 ° C
PACKAGE FACTOR
POWER RATING POWER RATING POWER RATING
ABOVE T
A
= 25 ° C
FK 1375 mW 11.0 mW/ ° C 880 mW 275 mW
J 1375 mW 11.0 mW/ ° C 880 mW 275 mW
MIN NOM MAX UNIT
AM26LS32AC, AM26LS32AI,
4.75 5 5.25
AM26LS33AC
V
CC
Supply voltage V
AM26LS32AM, AM26LS33AM 4.5 5 5.5
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
AM26LS32A ± 7
V
IC
Common-mode input voltage V
AM26LS33A ± 15
I
OH
High-level output current – 440 μ A
I
OL
Low-level output current 8 mA
AM26LS32AC, AM26LS33AC 0 70
T
A
Operating free-air temperature AM26LS32AI – 40 85 ° C
AM26LS32AM, AM26LS33AM – 55 125
over recommended ranges of V
CC
, V
IC
, and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
AM26LS32A 0.2
Positive-going
V
IT+
V
O
= V
OH
min, I
OH
= – 440 μ A V
input threshold voltage
AM26LS33A 0.5
AM26LS32A – 0.2
(2)
Negative-going
V
IT –
V
O
= 0.45 V , I
OL
= 8 mA V
input threshold voltage
AM26LS33A – 0.5
(2)
Hysteresis voltage
V
hys
50 mV
(V
IT+
– V
IT –
)
V
IK
Enable-input clamp voltage V
CC
= MIN, I
I
= – 18 mA – 1.5 V
AM26LS32AC,
2.7
AM26LS33AC
V
CC
= MIN, V
ID
= 1 V,
V
OH
High-level output voltage V
AM26LS32AM,
V
I(G)
= 0.8 V, I
OH
= – 440 μ A
AM26LS32AI, 2.5
AM26LS33AM
I
OL
= 4 mA 0.4
V
CC
= MIN, V
ID
= – 1 V,
V
OL
Low-level output voltage V
V
I(G)
= 0.8 V
I
OL
= 8 mA 0.45
Off-state V
O
= 2.4 V 20
I
OZ
(high-impedance state) V
CC
= MAX μ A
V
O
= 0.4 V – 20
output current
Other input at – 10 V to
V
I
= 15 V, 1.2
15 V
I
I
Line input current mA
Other input at – 15 V to
V
I
= – 15 V, – 1.7
10 V
I
I(EN)
Enable input current V
I
= 5.5 V 100 μ A
I
H
High-level enable current V
I
= 2.7 V 20 μ A
(1) All typical values are at V
CC
= 5 V, T
A
= 25 ° C, and V
IC
= 0.
(2) The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for
threshold levels only.
4 Submit Documentation Feedback Copyright © 1980 – 2007, Texas Instruments Incorporated
Product Folder Link(s): AM26LS32AC AM26LS32AI AM26LS33AC AM26LS32AM AM26LS33AM