Datasheet

1Z
1Y
G
G
1A
4
12
1
2
3
2Z
2Y
2A
7
6
5
3Z
3Y
3A
9
10
11
4Z
4Y
4A
15
14
13
AM26LS31, AM26LS31C, AM26LS31M
SLLS114J JANUARY 1979REVISED JANUARY 2014
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
Function Table
(1)
(Each Driver)
ENABLES OUTPUTS
INPUT
A
G G Y Z
H H X H L
L H X L H
H X L H L
L X L L H
X L H Z Z
(1) H = high level, L = low level,
X = irrelevant,
Z = high impedance (off)
Logic Diagram (Positive Logic)
2 Submit Documentation Feedback Copyright © 1979–2014, Texas Instruments Incorporated
Product Folder Links :AM26LS31 AM26LS31C AM26LS31M