Datasheet
www.ti.com
ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
AM26C31-EP
QUADRUPLE DIFFERENTIAL LINE DRIVER
SLLS871 – NOVEMBER 2007
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range
(2)
– 0.5 7 V
V
I
Input voltage range – 0.5 V
CC
+ 0.5 V
V
ID
Differential input voltage range – 14 14 V
V
O
Output voltage range – 0.5 7 V
I
IK
or
Input or output clamp current ± 20 mA
I
OK
I
O
Output current ± 150 mA
V
CC
current 200 mA
GND current – 200 mA
θ
JA
Package thermal impedance
(3) (4)
73 ° C/W
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range – 65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential output voltage (V
OD
), are with respect to the network ground terminal.
(3) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
ID
Differential input voltage ± 7 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current – 20 mA
I
OL
Low-level output current 20 mA
T
A
Operating free-air temperature – 55 125 ° C
Copyright © 2007, Texas Instruments Incorporated Submit Documentation Feedback 3