Datasheet
AFE4490
SBAS602F –DECEMBER 2012–REVISED OCTOBER 2013
www.ti.com
Bit D2 PDN_TX: Tx power-down
0 = The Tx is powered up (default after reset)
1 = Only the Tx module is powered down
Bit D1 PDN_RX: Rx power-down
0 = The Rx is powered up (default after reset)
1 = Only the Rx module is powered down
Bit D0 PDN_AFE: AFE power-down
0 = The AFE is powered up (default after reset)
1 = The entire AFE is powered down (including the Tx, Rx, and diagnostics blocks)
SPARE2: SPARE2 Register For Future Use (Address = 24h, Reset Value = 0000h)
D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12
0 0 0 0 0 0 0 0 0 0 0 0
D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 0 0 0 0 0
This register is a spare register and is reserved for future use.
Bits D[23:0] Must be '0'
SPARE3: SPARE3 Register For Future Use (Address = 25h, Reset Value = 0000h)
D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12
0 0 0 0 0 0 0 0 0 0 0 0
D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 0 0 0 0 0
This register is a spare register and is reserved for future use.
Bits D[23:0] Must be '0'
SPARE4: SPARE4 Register For Future Use (Address = 26h, Reset Value = 0000h)
D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12
0 0 0 0 0 0 0 0 0 0 0 0
D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 0 0 0 0 0
This register is a spare register and is reserved for future use.
Bits D[23:0] Must be '0'
68 Submit Documentation Feedback Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: AFE4490