Table 2. Error Code Definitions (continued)
Error Code Error # Description Most Probable Cause Possible Action
T2H_NACK 772 No response from target Target not connected/not Connect target and check is
powered correct power is applied
SMBD_LOW 1028 Unused but reserved for
backward compatibility
SMB_LOCKED 1284 Unused but reserved for
backward compatibility
ERR_NOTHINGTODO 5001 Calling the function with
specified values resulted in
nothing being done
ERR_VOLTAGE_LESSTHANZERO 5002 Specified Voltage must be
greater than 0
ERR_TEMPERATURE_LESSTHANZERO 5003 Specified temperature
must be greater than 0
ERR_CURRENT_EQUALSZERO 5004 Specified current cannot
be 0
ERR_NOT_IN_CAL_MODE 5010 Gas gauge was not in
Calibration mode/ could
not be put in calibration
mode
ERR_CALIBRATION_IN_FIRMWARE_FLASHWRITE 5020 Error writing flash in
calibration mode
ERR_CALIBRATION_IN_FIRMWARE_AFE 5021 Error in AFE calibration Value too large (Overflow) in
firmware
ERR_CALIBRATION_IN_FIRMWARE_PACKV 5022 Error in Pack voltage Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_PACKG 5023 Error in Pack gain Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_VGAIN 5024 Error in Voltage gain Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_CCIGAIN 5025 Error in Current gain Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFEXT1 5026 Error in external Value too large (Overflow) in
temperature 1 offset firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFEXT2 5027 Error in external Value too large (Overflow) in
temperature 2 offset firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFINT 5028 Error in internal Value too large (Overflow) in
temperature offset firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_ADCOFF 5029 Error in ADC offset Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_BRDOFF 5030 Error in Board offset Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_CCIOFF 5031 Error in CC offset Value too large (Overflow) in
calibration firmware
ERR_CALIBRATION_IN_FIRMWARE_RDRAWCALD 5032 Error in reading raw
ATA calibration data
ERR_CALIBRATION_IN_FIRMWARE_RSVD1 5033 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD2 5034 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD3 5035 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD4 5036 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD5 5037 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD6 5038 Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_UNDEFINED 5039 Unknown error code Software is obsolete
returned by hardware
ERR_DF_RD_REQ_B4_WR 5041 Data flash cannot be
written before reading the
remaining values in a
given class
ERR_INVALID_DATA_ENTERED 5042 Invalid data entered on
screen