Table 2. Error Code Definitions
Error Code Error # Description Most Probable Cause Possible Action
NO_ERROR 0 Successful (No errors)
LOST_SYNC 1 EV2x00 lost EV2x00 has outdated Contact TI to get EV2x00 with
synchronization firmware or drivers are latest firmware. Ensure latest
outdated. drivers for EV2x00 installed.
NO_USB 2 USB Connection Missing. No EV2x00 is connected. Close program, reboot, and
connect EV2x00 first.
BAD_PEC 3 Bad PEC on SMBus Possible Bad hardware. Replace EV2x00 / target board
WRONG_NUM_BYTES 5 Unexpected number of Unexpected hardware May need assistance from TI
bytes sent/received behavior.
T2H_UNKNOWN 6 SMBus communication Wrong kind of target make sure that the target mode
terminated unexpectedly / connected or target timing is accepts the SMB command
timed out or the bus was off Trim oscillator being sent
busy.
INCORRECT_PARAM 7 Invalid parameter type Incorrect parameter in call to Contact TI
passed to function - function. Software Bug or
especially Variant overflow
argument.
TIMEOUT_ERROR 8 USB Timeout No response on USB EV2x00 or driver problems or
software is not supposed to
wait for a response.
INVALID_DATA 9 AssemblePacket could not Bad data / bad packet. Possible version incompatibility
build a valid packet Software found problem with between BqTester and Module
data under test.
ERR_UNSOLICITED_PKT 10 Found an unsolicited Unexpected packet received. Make corrections to software
non-error packet when The packet may be a
looking for error packets response from a previous
transaction that failed or that
did not check the response.
COMPARE_DIFFERENT 11 Comparison failed and Flash comparison results in Module under test Flash failure
data read is different from mismatch. Possible Flash
srec failure or SMBus failure.
BQ80XRW_OCX_INTERNAL_ERROR 12 Problems with pointers Possible software bug or Contact TI
being NULL etc. overflow.
USER_CANCELLED_OPERATION 34 User clicked on cancel
button on progress bar
dialog
DF_CHECKSUM_MISMATCH 51 Data Flash checksum Flash comparison results in Module under test Flash failure
mismatch mismatch. Possible Flash
failure or SMBus failure.
IF_CHECKSUM_MISMATCH 52 Instruction Flash Flash comparison results in Module under test Flash failure
checksum mismatch mismatch. Possible Flash
failure or SMBus failure.
OPERATION_UNSUPPORTED 53 Unsupported type Software problem Check that Module under test
and bqTester versions are
compatible. Then contact TI
ERR_TOO_MANY_QUERIES 81 Not used
ERR_BAD_QUERY_ID 82 Not used
BAD_CRC 83 Packet was corrupted Too much noise or bad
during USB connection
communication
ERR_TOO_MANY_RESPONSES 84 Not used
ERR_NO_QUERIES_TO_DELETE 85 Not used
ERR_QUERY_UNAVAILABLE 86 Not used
ERR_NO_RESPONSES_TO_DELETE 87 Not used
ERR_RESPONSE_UNAVAILABLE 88 Not used
ERR_TMMT_NO_RESPONSE 90 Not used
T2H_ERR_TIMEOUT 92 SMBus communication Wrong kind of target make sure that the target mode
terminated unexpectedly / connected or target timing is accepts the SMB command
timed out or the bus was off Trim oscillator being sent
busy.
37
SLUU397A– February 2011– Revised May 2011 Error Code Definitions
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated