Areanyofthesetobeenabled?
a)AL_PDasAlarmOut
b)Power-upINTREFGEN
c)Power-upTEMPSENSOR
DevicePowersUp
StartsinManualModechannel0,
10Vinputrange.±
Programthe
InternalControlRegister(Page0,Register06h)
WillthedevicebeusedinAutoMode?
Willchannelselectionbeenabled?
(Default=channel0enabled)
No Yes
No Yes
No Yes
No Yes
Programthe
InternalControlRegister(Page0,Register06h)
Willanychannelinputrange
otherthan 10Vbeused?±
Programthe
RangeSelectRegister
(Page0,Registers10hto13h)
Willthealarmthresholdbeprogrammed
withorwithouthysteresis?
GotoPage1andProgramthe
PageSelectRegister(Page0,Register7Fh)
WritetheAlarmThresholdand
Hysteresisintothe
AlarmRegister(Page1,Registers00hto23h)
ReturntoPage0andProgramthe
PageSelectRegister(Page1,Register7Fh)
StartManualModeOperationor
AutoModeOperation
ManualMode
ChangeConfiguration ChangeConfiguration
AutoMode
ChangeMode
Continue Continue
Continue
ManualModeOperation
WritetoPage0,Register04h
AutoModeOperation
WritetoPage0,Register05h
ContinueOperationinConfiguredMode
WritetoPage0,Register00h
ADS8634
ADS8638
www.ti.com
SBAS541A –MAY 2011– REVISED AUGUST 2011
PROGRAMMING SEQUENCE
A typical programming sequence for the ADS8634/8 is shown in Figure 93.
Figure 93. Programming Flowchart