Datasheet
1 2
t
su1
t
su1
CS
R/C
External
DATACLK
CS Set Low, Discontinuous Ext DATACLK
t
su1
t
su1
R/C
CS
External
DATACLK
R/C Set Low, Discontinuous Ext DATACLK
t
su2
t
su2
CS
R/C
t
su3
BUSY
External
DATACLK
CS Set Low, Discontinuous Ext DATACLK
t
d9
ADS8517
www.ti.com
................................................................................................................................................. SLAS527A – SEPTEMBER 2008 – REVISED JUNE 2009
Table 6. Timing Requirements (T
A
= – 40 ° C to +85 ° C)
PARAMETER MIN TYP MAX UNIT
t
w1
Pulse duration, convert 0.04 5 µ s
t
d1
Delay time, BUSY from R/ C low 20 85 ns
t
w2
Pulse duration, BUSY low 2.3 2.5 µ s
t
d2
Delay time, BUSY, after end of conversion 90 ns
t
d3
Delay time, aperture 40 ns
t
conv
Conversion time 2.0 2.2 2.4 µ s
t
acq
Acquisition time 2.6 2.7 µ s
t
conv
+ t
acq
Cycle time 5 µ s
t
d4
Delay time, R/ C low to internal DATACLK output 171 ns
t
c1
Cycle time, internal DATACLK 92 96 98 ns
t
d5
Delay time, data valid to internal DATACLK high 2 3.5 ns
t
d6
Delay time, data valid after internal DATACLK low 41 43 ns
t
c2
Cycle time, external DATACLK 35 ns
t
w3
Pulse duration, external DATACLK high 15 ns
t
w4
Pulse duration, external DATACLK low 15 ns
t
su1
Setup time, R/ C rise/fall to external DATACLK high 15 ns
t
su2
Setup time, R/ C transition to CS transition 10 ns
t
d8
Delay time, data valid from external DATCLK high 2 25 40 ns
t
d9
Delay time, CS rising edge to external DATACLK rising edge 15 ns
t
d10
Delay time, previous data available after CS, R/ C low 1.8 2.2 µ s
t
su3
Setup time, BUSY transition to first external DATACLK 5 ns
t
d11
Delay time, final external DATACLK to BUSY rising edge 825 ns
t
su4
Setup time, TAG valid before rising edge of DATACLK 2 ns
t
h1
Hold time, TAG valid after rising edge of DATACLK 2 ns
Figure 32. Critical Timing Parameters
Copyright © 2008 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Link(s): ADS8517