Datasheet

www.ti.com
BUSY
STATUS
(N+1)th Accquisition (N+1)th Conversion
Error
Correction
Nth Conversion
Error
Correction
External
DATACLK
DATA
Nth Data (N+1)th Data
(N+2)th Accquisition
TAG = 0
No more
data to
shift out
No more
data to
shift out
TAG = 0
TAG = 0
TAG = 0
TAG = 0
R/C
EXT/INT tied high, CS and TAG are tied low
t
w1
+ t
su1
starts READ
t
w1
t
w1
t
d1
t
w2
t
d1
t
w2
t
d3
t
d11
t
d2
t
d3
t
d11
t
d2
t
su1
t
conv
t
acq
t
conv
t
acq
t
su3
t
su1
t
su3
1
12
1
2 12
1 12
1
2
12
ADS8508
SLAS433 SEPTEMBER 2005
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 3. Basic Conversion Timing - External DATACLK
Figure 4. Read After Conversion (Discontinuous External DATACLK)
8