Datasheet
N N+1
Manual Trigger Case 1
EOS
EOC
EOS
EOC
(programmed
Active Low)
Converter
State
Resume
N −th Sampling
>=3CCLK
EOC
EOS
N −th Conversion
=18 CCLK
Resume N+1 −th Sampling
>=3CCLK
EOC
EOS
N+1 −th Conversion
=18 CCLK
Read N−1 −th
Result
20 ns MIN
Read N −th
Result
20 ns MIN
Read N−1 −th
Result
1 CCLK MIN
Read N −th
Result
1 CCLK MIN
Converter
State
Resume N −th Sampling
>=3CCLK
EOC
N −th Conversion
=18 CCLK
Resume
N+1 −th Sampling
>=3CCLK
N+1 −th Conversion
=18 CCLK
Read N−1 −th
Result
20 ns MIN
Read N −th
Result
20 ns MIN
Read N−1 −th
Result
20 ns MIN
Read N −th
Result
20 ns MIN
40 ns MIN
EOC
(programmed
Active Low)
N N+1
40 ns MIN
POWERDOWN POWERDOWN
CONVST
CS
Read While Converting
0 ns MIN
CONVST
CS
Read While Sampling
POWER
DOWN
POWER
DOWN
CS
Read While Converting
Read While Sampling
CS
0 ns MIN
Manual Trigger Case 2 (wake up by CONVST)
6 CCLKs
6 CCLKs
20 ns MIN
20 ns MIN
20 ns MIN20 ns MIN
20 ns MIN
20 ns MIN
20 ns MIN
20 ns MIN
ADS8329
ADS8330
www.ti.com
................................................................................................................................................... SLAS516C – DECEMBER 2006 – REVISED JULY 2009
Figure 58. Read While Converting versus Read While Sampling with Auto Nap Power-Down
Total Acquisition + Conversion Cycle Time:
Automatic: = 21 CCLKs
Manual: ≥ 21 CCLKs
Manual + deep ≥ 4SCLK + 100 µ s + 3 CCLK + 18 CCLK +16 SCLK + 1 µ s
power-down:
Manual + nap power-down: ≥ 4 SCLK + 3 CCLK + 3 CCLK + 18 CCLK +16 SCLK
Manual + auto nap ≥ 4 SCLK + 3 CCLK + 3 CCLK + 18 CCLK +16 SCLK (use wakeup to resume)
power-down:
Manual + auto nap ≥ 1 CCLK + 3 CCLK + 3 CCLK + 18 CCLK +16 SCLK (use CONVST to resume)
power-down:
Copyright © 2006 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 29