Datasheet
ADS8319
SLAS600A –MAY 2008–REVISED SEPTEMBER 2013
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
MAXIMUM MAXIMUM NO MISSING
TRANSPORT
INTEGRAL DIFFERENTIAL CODES AT PACKAGE PACKAGE TEMPERATURE PACKAGE ORDERING
DEVICE MEDIA
LINEARITY LINEARITY RESOLUTION TYPE DESIGNATOR RANGE MARKING INFORMATION
QUANTITY
(LSB) (LSB) (BIT)
ADS8319IDGST 250
10 Pin MSOP DGS CEN
ADS8319IDGSR 2500
ADS8319I ±2.5 +1.5/–1 16 –40°C to 85°C
ADS8319IDRCT 250
10 Pin SON DRC CEP
ADS8319IDRCR 2500
ADS8319IBDGST 250
10 Pin MSOP DGS CEN
ADS8319IBDGSR 2500
ADS8319IB ±1.5 ±1.0 16 –40°C to 85°C
ADS8319IBDRCT 250
10 Pin SON DRC CEP
ADS8319IBDRCR 2500
(1) For the most current specifications and ordering information, see the Package Option Addendum at the end of this document, or see the
TI website at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted
(1)
VALUE UNIT
–0.3 to +VA + 0.3 V
+IN
±130 mA
–0.3 to 0.3 V
–IN
±130 mA
+VA to AGND –0.3 to 7 V
+VBD to BDGND –0.3 to 7 V
Digital input voltage to GND –0.3 to +VBD + 0.3 V
Digital output to GND –0.3 to +VBD + 0.3 V
T
A
Operating free-air temperature range –40 to 85 °C
T
stg
Storage temperature range –65 to 150 °C
Junction temperature (T
J
max) 150 °C
Power dissipation (T
J
Max – T
A
)/θ
JA
°C
MSOP package
θ
JA
thermal impedance 180 °C/W
ADS8319 is rated to MSL2 260C per the
Maximum MSOP reflow temperature
JSTD-020 specification
Power dissipation (T
J
Max – T
A
)/θ
JA
SON package
θ
JA
thermal impedance 70 °C/W
ADS8319 is rated to MSL2 260C per the
Maximum SON Reflow Temperature
JSTD-020 specification
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
2 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: ADS8319