Datasheet

ADS6445, ADS6444
ADS6443, ADS6442
SLAS531B MAY 2007REVISED DECEMBER 2009
www.ti.com
00010 200
00100 250
01000 333
10000 500
Any combination of above bits can also be programmed, resulting in a parallel combination of
the selected values. For example, 00101 is the parallel combination of 166||250 = 100
00101 100
Table 20. Serial Register H
REGISTER
BITS
(1)
ADDRESS
A4 - A0 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
<TERM DATA>
11 WORD-WISE CONTROL 0 0 0 0
LVDS INTERNAL TERMINATION - DATA OUTPUTS
(1) After a hardware or software reset, all register bits are cleared to 0.
D4-D0 <TERM DATA> LVDS internal termination for data outputs
00000 No internal termination
00001 166
00010 200
00100 250
01000 333
10000 500
Any combination of above bits can also be programmed, resulting in a parallel combination
of the selected values. For example, 00101 is the parallel combination of 166||250 = 100
00101 100
D10-D9 Only when 2-wire interface is selected
00 Byte-wise or bit-wise output, 1x frame clock
11 Word-wise output enabled, 0.5x frame clock
01,10 Do not use
24 Submit Documentation Feedback Copyright © 2007–2009, Texas Instruments Incorporated
Product Folder Link(s): ADS6445, ADS6444 ADS6443, ADS6442