Datasheet
ADS62P45, ADS62P44
ADS62P43, ADS62P42
SLAS561C –JULY 2007– REVISED FEBRUARY 2012
www.ti.com
Table 11.
A7–A0
D7 D6 D5 D4 D3 D2 D1 D0
(hex)
12 0 0 <LVDS TERMINATION> Internal termination programmability
D5–D3 <LVDS DATA TERM> Internal termination control for data outputs
000 No internal termination
001 300 Ω
010 180 Ω
011 110 Ω
100 150 Ω
101 100 Ω
110 81 Ω
111 60 Ω
D2–D0 <LVDS CLK TERM> Internal termination control for clock output
000 No internal termination
001 300 Ω
010 180 Ω
011 110 Ω
100 150 Ω
101 100 Ω
110 81 Ω
111 60 Ω
Table 12.
A7–A0
D7 D6 D5 D4 D3 D2 D1 D0
(hex)
13 0 0 0 <OFFSET FREEZE> 0 0 0 0
D4 <OFFSET FREEZE> Offset correction becomes inactive and the last estimated offset value is used to cancel the
offset
0 Offset correction active
1 Offset correction inactive
22 Submit Documentation Feedback Copyright © 2007–2012, Texas Instruments Incorporated
Product Folder Link(s): ADS62P45, ADS62P44 ADS62P43, ADS62P42