Table 11.
A7A0
D7 D6 D5 D4 D3 D2 D1 D0
(hex)
12 0 0 <LVDS TERMINATION> Internal termination programmability
D5D3 <LVDS DATA TERM> Internal termination control for data outputs
000 No internal termination
001 300
010 180
011 110
100 150
101 100
110 81
111 60
D2D0 <LVDS CLK TERM> Internal termination control for clock output
000 No internal termination
001 300
010 180
011 110
100 150
101 100
110 81
111 60
Table 12.
A7A0
D7 D6 D5 D4 D3 D2 D1 D0
(hex)
13 0 0 0 <OFFSET FREEZE> 0 0 0 0
D4 <OFFSET FREEZE> Offset correction becomes inactive and the last estimated offset value is used to cancel the
offset
0 Offset correction active
1 Offset correction inactive