Basic Test Procedure
www.ti.com
2 Basic Test Procedure
This section outlines the basic procedure for testing the EVM.
2.1 Test Block Diagram
The test set-up for general testing of the ADS58C48 with the TSW1200 capture card is shown in Figure 5.
Figure 5. Test Set-up Block Diagram
2.2 Verify Board Set-up
Verify jumper settings are in the correct position as outlined in Table 1.
Table 1. Default EVM Jumper Setting
Jumper Default Position Function
JP4 Short 1 - 2 DC supply for AVdd
JP5 Short 1 - 2 DC supply for DRVdd
JP6 Short 1 - 2 USB supply 5 V from PC
JP7 Short 1 - 2 DC supply 6 V
JP8 Short 1 - 2 DC supply 3.3 V
JP11 Short 1 - 2 SNRboost off for chA,B
JP12 Short 5 - 6 PDN normal
JP13 Short 1 - 2 SNRboost off for chC,D
JP16 Short 1 - 2 OPA disable
JP17 Short OPA gain
JP18 Short 1 - 2 OPA latch mode
JP19 Short 1 - 2 OPA gain strobe
2.3 Test Set-Up Connections
Connect ADS58C48 EVM to TSW1200 EVM
Connect 6V power to banana jack at J1; connect ground to J3
Connect USB cable to programming computer at J10
Connect USB and power supply jack to TSW1200
Connect Clock signal through appropriate BPF to J7
Connect input signal through appropriate BPF to J4, J6, J8 or J9
6
ADS58C48EVM SLAU313May 2010