Datasheet
www.ti.com
TEST ADS5292
8.2 Step 2: Single Tone FFT
• Select Single Tone FFT page at TSW1250 GUI.
• Connect Channel 1 of ADS5292EVM to a signal generator through a BP filter. If no BP filter is
presented, the result is not good.
• Set Amplitude of the signal generator to 11.5dBm
• Set Frequency of the signal generator to 10.02441406M to match the GUI.
• Change window option to Hanning. This is due to the fact that input signal and onboard CMOS clock
are noncoherent.
• Press Capture Single button to get the test result.
• Repeat for Channel 2...Channel 8.
Figure 10. User Interface: Single FFT Format
15
SLAU377–October 2011 ADS5292, 8-Channel, Analog-to-Digital Converter Evaluation Module
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated