Datasheet

www.ti.com
Launch TSW1250 GUI
7 Launch TSW1250 GUI
Launch TSW1250 GUI. The Message window displays this message to indicate that the setup of the
TSW1250EVM and ADS5292EVM is working properly. If a different message or an error message
appears, contact TI FAE.
1. Select ADS5292_2W, 12bits, from the GUI.
2. Select LSB First.
3. ADC Sampling Rate (Fs) is fixed at 80 MHz; this is the onboard CMOS clock frequency.
4. ADC Input Frequency enter 10M and the GUI calculates the real coherent frequency (Fc) to
10.02441406M.
Figure 6. TSW1250 GUI Launch
11
SLAU377October 2011 ADS5292, 8-Channel, Analog-to-Digital Converter Evaluation Module
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated