Datasheet

www.ti.com
Optional Configurations
3 Optional Configurations
3.1 THS4509 Input Op-Amp Configuration
The default analog input configuration is a transformer coupling through T1 and T2 for channel A, and T3
and T4 for channel B. The optional configuration for analog input is through an Operational-Amplifier
(OPA), THS4509. The changes required to modify the transformer coupled input to the OPA-driven input
are shown in Table 3.
Table 3. Jumper Setting for Transformer-Coupled or OPA-Driven Input
Jumpers or 0 Ω Transformer-Coupled Input (default) OPA-Driven Input
R119 Install Do not install
R123 Install Do not install
R120 Do not install install
R129 Do not install install
R143 Install Do not install
R141 Install Do not install
R131 Do not install Install
R132 Do not install Install
R93 Install Do not install
R94 Install Do not install
R95 Do not install Install
R96 Do not install Install
R97 Install Do not install
R98 Install Do not install
R99 Do not install Install
R114 Do not install Install
SJP3 Shunt 2 - 3, default Shunt 1 - 2
SJP4 Shunt 2 - 3, default Shunt 1 - 2
J11 and J13 are the power supply for THS4509. An on-board layout option for an LPF or BPF is available
between the amplifier and the ADC. By default, the filter is bypassed allowing the flexibility of designing
according to the desired specifications.
3.2 On-Board CDCE72010 Clock
The default clock input configuration is 1:4 transformer coupling through T6. The optional configuration is
through clock driver CDCE72010. The changes required to modify the transformer coupled clock input to
clock driver input are shown in Table 4.
Table 4. Jumper Setting for Transformer-Coupled or CDCE72010 Input
Jumper Transformer-Coupled (Default) CDCE72010
J14 shunt open
JP20 Shunt 1 - 2 Shunt 1 - 2
JP21 Shunt 1 - 2 Shunt 1 - 2
J18 open open
R121 0 Ω DNI
R122 DNI 0 Ω
SJP7 Short 1 - 2 Short 3 - 4
SJP6 Short 3 - 4 Short 5 - 6
9
SLAU333AMarch 2011Revised June 2013 ADS42xx EVM
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated