Datasheet
Basic Test Procedure
www.ti.com
Table 1. Default ADS42xx/58C28 EVM Rev B Jumper Setting for Serial
Interface
(1)
(continued)
Jumper Default position Function
JP 13 Open
JP14 Short 7 - 8 ADC 2’s complement, DDR LVDS
JP5 Short 1 - 2 ADC CTRL3, normal operation
JP6 Short 1 - 2 ADC CTRL2, normal operation
JP7 Short 1 - 2 ADC CTRL1, normal operation
JP 18 Short 1 - 2 Ext Buffer
JP 23 Short 1 - 2 Ext Buffer
JP 24 Short 1 - 2 Ext Buffer
JP 25 Short 1 - 2 Ext Buffer
Table 2. Parallel Interface with Pin Control of the ADS42xx/58C28 EVM Rev B
Jumper Setting
Jumper Position Function
JP8 Short 1 - 2 ADC SCLK for parallel control
JP9 Short 1 - 2 ADC SDATA for parallel control
JP10 Short 1 - 2 ADC SEN for parallel control
JP11 Short 1 - 2 ADC parallel control
2.3 Test Set-up Connections
• Connect the ADS42xx/ADS58C28 EVM to the TSW1400 EVM
• Connect 5-V power to the banana jack at J10; connect ground to J12
• Connect the USB cable to the programming computer at J17
• Connect the USB and power supply jack to TSW1400
• Connect clock signal through appropriate BPF to J19
• Connect input signal through appropriate BPF to J6, J3
2.4 TSW1400 Quick start Operation
See the TSW1400 user’s guide (SLWU079B) for a more detailed explanation of the TSW1400 set-up and
operation. This document assumes the TSW1400 software is installed and functioning properly. The front
panel of the TSW1400 is shown in Figure 4.
• Download and install TSW1400 GUI (High Speed Data Converter Pro GUI Installer, vx.x (Rev.E)) and
TSW140xEVM .ini File Update List from www.ti.com/tool/tsw1400evm
• Open High Speed Data Converter Pro
6
ADS42xx EVM SLAU333A–March 2011–Revised June 2013
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated