Datasheet

ADS1259
SBAS424D JUNE 2009 REVISED AUGUST 2011
www.ti.com
OFC0: OFFSET CALIBRATION BYTE 0, LEAST SIGNIFICANT BYTE (Address = 3h)
7 6 5 4 3 2 1 0
OFC07 OFC06 OFC05 OFC04 OFC03 OFC02 OFC01 OFC00
Reset value = 00000000b.
OFC1: OFFSET CALIBRATION BYTE 1 (Address = 4h)
7 6 5 4 3 2 1 0
OFC15 OFC14 OFC13 OFC12 OFC11 OFC10 OFC09 OFC08
Reset value = 00000000b.
OFC2: OFFSET CALIBRATION BYTE 2, MOST SIGNIFICANT BYTE (Address = 5h)
7 6 5 4 3 2 1 0
OFC23 OFC22 OFC21 OFC20 OFC19 OFC18 OFC17 OFC16
Reset value = 00000000b.
FSC0: FULL-SCALE CALIBRATION BYTE 0, LEAST SIGNIFICANT BYTE (Address = 6h)
7 6 5 4 3 2 1 0
FSC07 FSC06 FSC05 FSC04 FSC03 FSC02 FSC01 FSC00
Reset value = 00000000b.
FSC1: FULL-SCALE CALIBRATION BYTE 1 (Address = 7h)
7 6 5 4 3 2 1 0
FSC15 FSC14 FSC13 FSC12 FSC11 FSC10 FSC09 FSC08
Reset value = 00000000b.
FSC2: FULL-SCALE CALIBRATION BYTE 2, MOST SIGNIFICANT BYTE (Address = 8h)
7 6 5 4 3 2 1 0
FSC23 FSC22 FSC21 FSC20 FSC19 FSC18 FSC17 FSC16
Reset value = 01000000b.