Datasheet
www.ti.com
STANDBY MODE WITH
Standby Mode
Begin Calibration
Data Ready After Calibration
t
10
t
12
DRDY/DOUT 23
1 24 25
22 21 0 23
SCLK
ADS1232
ADS1234
SBAS350F – JUNE 2005 – REVISED FEBRUARY 2008
To force an offset-calibration with Standby mode, shift
OFFSET-CALIBRATION 25 SCLKs and take the SCLK pin high to enter
Standby mode. Offset-calibration then begins after
Offset-calibration can be set to run immediately after
wake-up; see Figure 38 for the appropriate timing.
exiting Standby mode. This is useful when the
Note the extra time needed after wake-up for
ADS1232/4 is put in Standby mode for long periods
calibration before data are ready. The first data after
of time, and offset-calibration is desired afterwards to
Standby mode with offset-calibration is fully settled
compensate for temperature or supply voltage
and can be used right away.
changes.
Figure 38. Standby Mode with Offset-Calibration Timing (can be used for single conversions)
SYMBOL DESCRIPTION MIN MAX UNITS
SPEED = 1 103 103 ms
Data ready after exiting Standby mode
t
12
(1)
and calibration
SPEED = 0 803 803 ms
(1) Values given for f
CLK
= 4.9152MHz. For different f
CLK
frequencies, scale proportional to CLK period. Expect a ± 3% variation when an
internal oscillator is used.
22 Copyright © 2005 – 2008, Texas Instruments Incorporated
Product Folder Link(s): ADS1232 ADS1234