Datasheet

ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
(1)
ADS1225
ADS1226
SBAS346C MAY 2006 REVISED JANUARY 2009 .......................................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
For the most current package and ordering information, see the Package Option Addendum located at the end of
this data sheet or see the TI web site at www.ti.com.
Over operating free-air temperature range, unless otherwise noted.
ADS1225, ADS1226 UNIT
AVDD to GND 0.3 to +6 V
DVDD to GND 0.3 to +6 V
100, momentary mA
Input current
10, continuous mA
Analog input voltage to GND 0.3 to AVDD +0.3 V
Digital input voltage to GND 0.3 to AVDD +0.3 V
Maximum junction temperature +150 ° C
Operating temperature range 55 to +125 ° C
Storage temperature range 50 to +150 ° C
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
2 Submit Documentation Feedback Copyright © 2006 2009, Texas Instruments Incorporated
Product Folder Link(s): ADS1225 ADS1226