Datasheet
SBAS286C − JUNE 2003 − REVISED JANUARY 2009
www.ti.com
2
ORDERING INFORMATION
(1)
PRODUCT PACKAGE−LEAD
PACKAGE
DESIGNATOR
SPECIFIED
TEMPERATURE
RANGE
PACKAGE
MARKING
ORDERING
NUMBER
TRANSPORT
MEDIA, QUANTITY
ADS1224
TSSOP-20
PW
−40°C to +85°C
ADS1224
ADS1224IPWT Tape and Reel, 250
ADS1224
TSSOP-20
PW
−40
°
C to +85
°
C
ADS1224
ADS1224IPWR Tape and Reel, 2500
(1)
For the most current specification and package information, refer to our web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted
(1)
ADS1224 UNIT
AVDD to GND −0.3 to +6 V
DVDD to GND −0.3 to +6 V
Input current
100, momentary mA
Input current
10, continuous mA
Analog input voltage to GND −0.3 to AVDD + 0.3 V
Digital input voltage to GND −0.3 to DVDD + 0.3 V
Maximum Junction Temperature +150 °C
Operating Temperature Range −55 to +125 °C
Storage Temperature Range −60 to +150 °C
Lead Temperature (soldering, 10s) +300 °C
(1)
Stresses above these ratings may cause permanent damage.
Exposure to absolute maximum conditions for extended periods
may degrade device reliability. These are stress ratings only, and
functional operation of the device at these or any other conditions
beyond those specified is not implied.
This integrated circuit can be damaged by ESD. Texas
Instruments recommends that all integrated circuits be
handled with appropriate precautions. Failure to observe
proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to
complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.