ADS1258EVM-PDK Kit Operation
8.4.2 Connecting a Laboratory Power Supply
A laboratory power supply can be connected through terminal block J14 on the MMB0, as shown in
Figure 7. Both unipolar and bipolar configurations are supported.
To use a unipolar lab power-supply configuration:
• Disconnect J12 on the MMB0.
• Connect a +5V dc supply to the +5VD terminal on J14.
• Connect ground of the dc supply to the GND terminal on J14.
For bipolar mode, also connect a –5V dc supply to the –5VA terminal on J14.
It is not necessary to connect +5V dc supply voltage to the +5VA terminal on J14 if the +5V/+5VA position
on J13 is shorted.
Figure 7. Laboratory Power-Supply Connection
15