7.4 Default Jumper Settings and Switch Positions
Figure 3 shows the jumpers found on the EVM and the factory default conditions for each one.
Figure 3. ADS1258EVM Default Jumper Locations
The jumpers on J4 provide a convenient way to measure the current for any of the power-supply currents:
AVDD (analog +V power), DVDD (digital power), AVSS (analog –V power), or the ground connections
VGND and DGND. Simply remove the jumper for the appropriate power supply and use a current meter
between the jumper pins. The supply voltage for the digital supply (DVDD) can also be selected to be
either 1.8V or 3.3V; see Table 6.
Table 8 provides a list of switches found on the EVM and the factory default conditions for each one.
Table 8. List of Switches
SWITCH DEFAULT POSITION SWITCH DESCRIPTION
S1 Left REF positive
S2 Left REF negative