Datasheet
ADS1118
SBAS457D –OCTOBER 2010–REVISED OCTOBER 2013
www.ti.com
Bit 8 MODE: Device operating mode
This bit controls the ADS1118 operating mode.
0 = Continuous conversion mode
1 = Power-down and single-shot mode (default)
Bits[7:5] DR[2:0]: Data rate
These bits control the data rate setting.
000 = 8 SPS 100 = 128 SPS (default)
001 = 16 SPS 101 = 250 SPS
010 = 32 SPS 110 = 475 SPS
011 = 64 SPS 111 = 860 SPS
Bit 4 TS_MODE: Temperature sensor mode
This bit configures the ADC to convert temperature or input signals.
0 = ADC mode (default)
1 = Temperature sensor mode
Bit 3 PULL_UP_EN: Pull-up enable
This bit enables a weak pull-up resistor on the DOUT/DRDY pin. When enabled, a 400-kΩ resistor connects
the bus line to supply. When disabled, the DOUT/DRDY pin floats.
0 = Pull-up resistor disabled on DOUT/DRDY pin
1 = Pull-up resistor enabled on DOUT/DRDY pin (default)
Bits[2:1] NOP[1:0]: No operation
The NOP[1:0] bits control whether data are written to the Config register or not. In order for data to be written to
the Config register, the NOP[1:0] bits must be '01'. Any other value results in a NOP command. DIN can be
held high or low during SCLK pulses without data being written to the Config register.
00 = Invalid data, do not update the contents of the Config register
01 = Valid data, update the Config register (default)
10 = Invalid data, do not update the contents of the Config register
11 = Invalid data, do not update the contents of the Config register
Bit 0 Not used
Always reads '1'
22 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: ADS1118