Datasheet

www.ti.com
ADDITIONAL RECOMMENDATIONS
ADS1000
SBAS357A SEPTEMBER 2006 REVISED OCTOBER 2007
stabilized; this momentary spike can damage the
ADS1000. Sometimes this damage is incremental
The ADS1000 is fabricated in a small-geometry
and results in slow, long-term failure which can be
low-voltage process. The analog inputs feature
distastrous for permanently installed, low-
protection diodes to the supply rails. However, the
maintenance systems.
current-handling ability of these diodes is limited, and
the ADS1000 can be permanently damaged by If using an op amp or other front-end circuitry with the
analog input voltages that remain more than ADS1000, be sure to take the performance
approximately 300mV beyond the rails for extended characteristics of this circuitry into account; a chain is
periods. One way to protect against overvoltage is to only as strong as its weakest link.
place current-limiting resistors on the input lines. The
Any data converter is only as good as its reference.
ADS1000 analog inputs can withstand momentary
For the ADS1000, the reference is the power supply,
currents of as large as 10mA.
and the power supply must be clean enough to
The previous paragraph does not apply to the I
2
C achieve the desired performance. If a power-supply
ports, which can both be driven to 6V regardless of filter capacitor is used, it should be placed close to
the supply. the V
DD
pin, with no vias placed between the
capacitor and the pin. The trace leading to the pin
If the ADS1000 is driven by an op amp with high
should be as wide as possible, even if it must be
voltage supplies, such as ± 12V, protection should be
necked down at the device.
provided, even if the op amp is configured so that it
will not output out-of-range voltages. Many op amps
seek to one of the supply rails immediately when
power is applied, usually before the input has
14 Submit Documentation Feedback Copyright © 2006 2007, Texas Instruments Incorporated
Product Folder Link(s): ADS1000