Datasheet
www.ti.com
Software and SPI Registers
3.7 Input Common Mode
Jumper P21 can be used to force a common mode on the ADC inputs. In its default configuration, the
evaluation board has capacitively coupled ADC inputs, and using the Input Common Mode jumper will not
have any effect.
3.8 Default Jumper and Switch Settings
On delivery, the board’s jumpers and switches should be set as defined in Table 1. Any directions are
defined when the board is positioned as in Figure 1.
Table 1. Board Jumpers and Switches
Jumper or Switch Default Position
P2 Open
P4 Closed
P13 Closed
P15 Closed
P17 Closed
P21 Open
S2 Left (On Board Clock)
S3 Left (Sleep mode not active)
4 Software and SPI Registers
The ADC12EU050 evaluation board is designed to be used with the WaveVision5™ data capture board
and software. The latest version of the WaveVision5™ software must be used.
4.1 SPI Registers
As described in the ADC12EU050 datasheet, there are many user registers accessible via the SPI
interface.
These registers can all be programmed via the “Registers” tab in the WaveVision5™ software.
All registers and values are described in the ADC12EU050 data sheet, which is available from the Texas
Instruments website.
5
SNAU020–September 2013 ADC12EU050: Ultra-low Power, Octal, 12-bit, 45MSPS Sigma-Delta Analog-
to-Digital Converter
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated