Datasheet

2
1f
2
6f
2
2f
10
A
A++A
log20=THD
ADC124S051
www.ti.com
SNAS260E NOVEMBER 2004REVISED NOVEMBER 2004
TOTAL HARMONIC DISTORTION (THD) is the ratio, expressed in dB or dBc, of the rms total of the first five
harmonic components at the output to the rms level of the input signal frequency as seen at the output. THD is
calculated as:
where
Af
1
is the RMS power of the input frequency at the output and
A Af
2
through f
6
are the RMS power in the first 5 harmonic frequencies. (2)
THROUGHPUT TIME is the minimum time required between the start of two successive conversion. It is the
acquisition time plus the conversion and read out times. In the case of the ADC124S051, this is 16 SCLK
periods.
Copyright © 2004, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Links: ADC124S051