Datasheet

2.0 Applications Information
(Continued)
The sample-and-hold error specifications are included in the
error and timing specifications of the A/D. The hold step and
gain error sample/hold specs are included in the ADC10154/
ADC10158’s total unadjusted, linearity, gain and offset error
specifications, while the hold settling time is included in the
A/D’s maximum conversion time specification. The hold
droop rate can be thought of as being zero since an unlim-
ited amount of time can pass between a conversion and the
reading of data. The data is lost after a new conversion has
been completed.
Protecting the Analog Inputs
DS011225-25
Diodes are 1N914.
The protection diodes should be able to withstand the output current of the op amp under current limit.
Zero-Shift and Span-Adjust for Signed or Unsigned, Unipolar, Single-Ended
Multiplexer Assignment, Analog Input Range of 2V V
IN
4.5V
DS011225-26
*1% resistors
ADC10154/ADC10158
www.national.com21