Datasheet

ADC081S051
SNAS309E APRIL 2005REVISED MARCH 2013
www.ti.com
ADC081S051 Timing Specifications
The following specifications apply for V
A
= +2.7V to 5.25V, GND = 0V, f
SCLK
= 4 MHz to 10 MHz, C
L
= 25 pF,
f
SAMPLE
= 200 ksps to 500 ksps, Boldface limits apply for T
A
= T
MIN
to T
MAX
: all other limits T
A
= 25°C.
Symbol Parameter Conditions Typical Limits Units
t
CS
Minimum CS Pulse Width 10 ns (min)
t
SU
CS to SCLK Setup Time 10 ns (min)
t
EN
Delay from CS Until SDATA TRI-STATE Disabled
(1)
20 ns (max)
V
A
= +2.7V to +3.6V 40 ns (max)
t
ACC
Data Access Time after SCLK Falling Edge
(2)
V
A
= +4.75V to +5.25V 20 ns (max)
t
CL
SCLK Low Pulse Width 0.4 x t
SCLK
ns (min)
t
CH
SCLK High Pulse Width 0.4 x t
SCLK
ns (min)
V
A
= +2.7V to +3.6V 7 ns (min)
t
H
SCLK to Data Valid Hold Time
V
A
= +4.75V to +5.25V 5 ns (min)
25 ns (max)
V
A
= +2.7V to +3.6V
6 ns (min)
t
DIS
SCLK Falling Edge to SDATA High Impedance
(3)
25 ns (max)
V
A
= +4.75V to +5.25V
5 ns (min)
t
POWER-
Power-Up Time from Full Power-Down 1 µs
UP
(1) Measured with the timing test circuit shown in Figure 2 and defined as the time taken by the output signal to cross 1.0V.
(2) Measured with the timing test circuit shown in Figure 2 and defined as the time taken by the output signal to cross 1.0V or 2.0V.
(3) t
DIS
is derived from the time taken by the output to change by 0.5V with the timing test circuit shown in Figure 2. The measured number
is then adjusted to remove the effects of charging or discharging the load capacitance. This means that t
DIS
is the true bus relinquish
time, independent of the bus loading.
6 Submit Documentation Feedback Copyright © 2005–2013, Texas Instruments Incorporated
Product Folder Links: ADC081S051