3. Setup & Test - Self-Run Mode
The S6400 readers are shipped in the factory-default “Self-Run” (Wiegand data
output) mode, allowing them to operate independently of a computer or security
control panel. Follow the instructions below to activate the readers in this mode and
verify their functionality.
1. Connect the harness with the RS-485 converter to one reader. The RS-485
converter is not needed for this test, however the harness includes a
receptacle for the power supply, which is required.
Note:
Be sure that the remaining unconnected wires do not touch each
other, as this may cause operation in “Self Run” mode to fail.
2. Connect the power supply to the power connector on the RS-485 converter
harness.
Caution:
The connector on the power supply must be set at positive tip or
interior output voltage. Be sure the arrow on the tip of the power
supply is lined up with the (-) setting on the power supply output
barrel indicating negative barrel (positive tip) voltage.
3. Plug the power supply into an AC power source using the appropriate
adapter supplied.
4. Test reader by slowly bringing one of the pre-programmed ISO/IEC 15693
compliant badges within close range of the reader. As soon as the badge is
within the reader’s range, the reader will beep and the LED will flash once
to indicate a successful read has taken place.