User's Manual

11
11. Wiring Alternatives for Lights and Sound
Several operational alternatives exist for the LEDs and the audio transducer. The
following table lists the associated wires.
Optional Connections
Orange Green LED
Brown Red LED
Yellow Audio
Tying any of these wires to ground while the unit is powered will cause activation
of the associated feature. For example, many existing readers have an LED which
glows red by default when the reader is at rest. Tying the brown wire permanently
to ground will cause the S6400 reader to have the same effect. In this state, upon
activation by a card, the light will momentarily switch to green, and then back to
red.
As another example, if the unit is tied to a controller, which momentarily unlocks a
door, it may be desired to have the green light glow and the audio transducer sound
for the duration in which the door is unlocked. Tying the yellow and orange wires
to the (-) controller output to which the door lock is connected will produce this
effect.
For more information regarding the optional wiring connections, including the hold
feature, consult the User’s Guide.
12. Self-Test Mode
The readers are equipped with a self-test mode that allows them to cycle through
their functions and report the results through the LED. To put the reader into self-
test mode, connect the following wire pairs together, then apply power to the reader.
Wire: Green Violet White Blue
Connect To:
Orange Brown Yellow Gray
Proper operation is indicated by the LED blinking green. The LED will turn to
solid red and the unit will beep once within three seconds after a card is brought into
the field. The flashing green light will return once the card has been removed from
the field. See the User’s Guide for more information about self-test mode.
CAUTION:
The unit is not intended to operate in self-test mode
indefinitely, as it operates above its standard duty-
Leaving a badge in the field longer than 3 minutes while the
unit is in self-test mode may cause the unit to overheat.
* Information submitted for FCC, Industry Canada,
RTTE, CE & ETL certification: A92ACS6410 &
A92ACS6420 *