Datasheet

74ACT11374
OCTAL EDGE-TRIGGERED D-TYPE FLIP-FLOP
WITH 3-STATE OUTPUTS
SCAS217A – JULY 1987 – REVISED APRIL 1996
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
TEST
CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
I
OH
=50A
4.5 V 4.4 4.4
I
OH
= –
50
A
5.5 V 5.4 5.4
V
OH
I
OH
=24mA
4.5 V 3.94 3.8
V
OH
I
OH
= –
24
mA
5.5 V 4.94 4.8
I
OH
= –75 mA
5.5 V 3.85
I
OL
=50 A
4.5 V 0.1 0.1
I
OL
=
50
A
5.5 V 0.1 0.1
V
OL
I
OL
=24mA
4.5 V 0.36 0.44
V
OL
I
OL
=
24
mA
5.5 V 0.36 0.44
I
OL
= 75 mA
5.5 V 1.65
I
OZ
V
O
= V
CC
or GND 5.5 V ±0.5 ±5 A
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 A
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 8 80 A
I
CC
One input at 3.4 V, Other inputs at GND or V
CC
5.5 V 0.9 1 mA
C
i
V
I
= V
CC
or GND 5 V 4 pF
C
o
V
O
= V
CC
or GND 5 V 10 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
CC
.
timing requirements over recommended ranges of supply voltages and operating free-air
temperature (unless otherwise noted) (see Figure 1)
T
A
= 25°C
MIN
MAX
UNIT
MIN MAX
MIN
MAX
UNIT
f
clock
Clock frequency 0 55 0 55 MHz
t
w
Pulse duration, CLK low or CLK high 9 9 ns
t
su
Setup time, data before CLK 3 3 ns
t
h
Hold time, data after CLK 5.5 5.5 ns
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX
MIN
MAX
UNIT
f
max
55 70 55 MHz
t
PLH
CLK
Any Q
1.5 8.5 10.7 1.5 12.4
ns
t
PHL
CLK
An
y
Q
1.5 8.5 11.3 1.5 13
ns
t
PZH
OE
Any Q
1.5 7.5 11 1.5 12.3
ns
t
PZL
OE
An
y
Q
1.5 7.5 11 1.5 12.3
ns
t
PHZ
OE
Any Q
1.5 11 12.7 1.5 13.2
ns
t
PLZ
OE
An
y
Q
1.5 8 10 1.5 10.8
ns