Datasheet

74ACT11373
OCTAL TRANSPARENT D-TYPE LATCH
WITH 3-STATE OUTPUTS
SCAS015B – JUNE 1987 – REVISED APRIL 1996
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
TEST
CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
I
OH
=50A
4.5 V 4.4 4.4
I
OH
= –
50
A
5.5 V 5.4 5.4
V
OH
I
OH
=24mA
4.5 V 3.94 3.8
V
OH
I
OH
= –
24
mA
5.5 V 4.94 4.8
I
OH
= –75 mA
5.5 V 3.85
I
OL
=50 A
4.5 V 0.1 0.1
I
OL
=
50
A
5.5 V 0.1 0.1
V
OL
I
OL
=24mA
4.5 V 0.36 0.44
V
OL
I
OL
=
24
mA
5.5 V 0.36 0.44
I
OL
= 75 mA
5.5 V 1.65
I
OZ
V
O
= V
CC
or GND 5.5 V ±0.5 ±5 A
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 A
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 8 80 A
I
CC
One input at 3.4 V, Other inputs at GND or V
CC
5.5 V 0.9 1 mA
C
i
V
I
= V
CC
or GND 5 V 4 pF
C
o
V
O
= V
CC
or GND 5 V 10 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
CC
.
timing requirements over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
T
A
= 25°C
MIN
MAX
UNIT
MIN MAX
MIN
MAX
UNIT
t
w
Pulse duration, LE high 5 5 ns
t
su
Setup time, data before LE 3.5 3.5 ns
t
h
Hold time, data LE 3.5 3.5 ns
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
D
Q
1.5 7.5 10.3 1.5 11.8
ns
t
PHL
D
Q
1.5 6.5 9.3 1.5 10
ns
t
PLH
LE
Any Q
1.5 8.5 11.3 1.5 13
ns
t
PHL
LE
An
y
Q
1.5 8.5 10.9 1.5 12.2
ns
t
PZH
OE
Any Q
1.5 7 10.7 1.5 12.5
ns
t
PZL
OE
An
y
Q
1.5 7.5 10.9 1.5 12
ns
t
PHZ
OE
Any Q
1.5 10 12.1 1.5 12.2
ns
t
PLZ
OE
An
y
Q
1.5 7.5 9.5 1.5 10.1
ns