electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C 54ACT11030 74ACT11030
UNIT
PARAMETER
TEST
CONDITIONS
V
CC
MIN TYP MAX MIN MAX MIN MAX
UNIT
I
OH
=50µA
4.5 V 4.4 4.4 4.4
I
OH
= –
50
µ
A
5.5 V 5.4 5.4 5.4
V
OH
I
OH
=24mA
4.5 V 3.94 3.7 3.8
V
V
OH
I
OH
= –
24
mA
5.5 V 4.94 4.7 4.8
V
I
OH
= – 50 mA
†
5.5 V 3.85
I
OH
= –75 mA
†
5.5 V 3.85
I
OL
=50µA
4.5 V 0.1 0.1 0.1
I
OL
=
50
µ
A
5.5 V 0.1 0.1 0.1
V
OL
I
OL
=24mA
4.5 V 0.36 0.5 0.44
V
V
OL
I
OL
=
24
mA
5.5 V 0.36 0.5 0.44
V
I
OL
= 50 mA
†
5.5 V 1.65
I
OL
= 75 mA
†
5.5 V 1.65
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 4 80 40 µA
∆I
CC
‡
One input at 3.4 V,
Other inputs at V
CC
or GND
5.5 V 0.9 1 1 mA
C
i
V
I
= V
CC
or GND 5 V 3.5 pF
†
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
CC
.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C 54ACT11030 74ACT11030
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
t
PLH
A thru H
Y
1.5 5.4 8.1 1.5 8.8 1.5 8.5
ns
t
PHL
A
thr
u
H
Y
1.5 5.9 7.8 1.5 9.3 1.5 8.7
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance per gate C
L
= 50 pF, f = 1 MHz 41 pF