Datasheet

74ACT11004
HEX INVERTER
SCAS215B JANUARY 1988 REVISED JUNE 1997
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
TEST
CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
I
OH
= 50 A
4.5 V 4.4 4.4
I
OH
=
50
A
5.5 V 5.4 5.4
V
OH
I
OH
= 24 mA
4.5 V 3.94 3.8
V
I
OH
=
24
mA
5.5 V 4.94 4.8
I
OH
= 75 mA
5.5 V 3.85
I
OL
=50 A
4.5 V 0.1 0.1
I
OL
=
50
A
5.5 V 0.1 0.1
V
OL
I
OL
=24mA
4.5 V 0.36 0.44
V
I
OL
=
24
mA
5.5 V 0.36 0.44
I
OL
= 75 mA
5.5 V 1.65
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 A
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 4 40 A
I
CC
One input at 3.4 V, Other inputs at GND or V
CC
5.5 V 0.9 1 mA
C
i
V
I
= V
CC
or GND 5 V 3.5 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ns.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V
CC
.
switching characteristics over recommended ranges of supply voltage and free-air temperature
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A
Y
1.5 5.3 9 1.5 9.7
ns
t
PHL
A
Y
1.5 6.4 8.7 1.5 9.6
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance per inverter C
L
= 50 pF, f = 1 MHz 32 pF