Installation Manual
Table Of Contents
- Safety summary
- About this manual
- Introduction to EXPLORER 323
- To install the system
- To get started
- Before you start
- To switch on the EXPLORER 323
- To connect to the LAN interface
- To connect your WLAN-enabled device
- The EXPLORER Connect app
- To access the web interface
- To enter the SIM PIN for the terminal
- To register with the BGAN network
- Mounting calibration
- To start and stop data connections
- To make phone calls over BGAN
- To use the EXPLORER 323
- Configuration with web interface
- The web interface
- To control data connections from web interface
- To set up your data connection packages
- Multiple data connections
- Status information
- The Control panel
- To use the logs
- Terminal settings
- To set up the interfaces
- To manage VoIP phones or smartphones (Not M2M)
- Advanced LAN
- To manage connected devices (Traffic control)
- To set up tracking and location reporting
- Support features
- Advanced settings
- Passwords
- To set up user permissions
- To restore factory settings
- SIM PIN for BGAN
- To save or load a configuration
- Connection watchdog (Link monitoring)
- Terminal watchdog
- Data limits
- Call charges
- Remote management
- Remote control of tracking
- Power save
- To configure data connection types and filters
- Help desk
- Reset button
- Security
- To enter the SIM PIN in the web interface
- Maintenance and troubleshooting
- Specifications
- Command reference
- Conformity
- Glossary
- Index
Chapter 5: Configuration with web interface
98-169085-B Multiple data connections 56
To set up dedicated connections
You can set up dedicated connections for the EXPLORER 323, e.g. for M2M equipment.
1. From the Dashboard, click New connection package to create a new connection
package, or
click
in the right side of the tile with the connection package that you want to change
and click Properties.
2. Under Type, select the connection type you want.
• Shared connection. This is the default setting, a shared background data connection.
ACA is disabled and there are no dedicated connections.
• Dedicated DHCP. This is a dedicated connection using DHCP. With this type, any
DHCP-enabled unit you connect to the EXPLORER 323 will get a new dedicated
connection used only for that unit. When you disconnect the unit, the connection is
removed after a few minutes. Each new connection gets its own tile on the Dashboard
as long as it is running. In the example below, three units are connected using Dedicated
DHCP. ACA is enabled for all Dedicated DHCP connections and cannot be disabled,
unless you delete the connection package.
• Dedicated static IP. This is a dedicated connection using a static IP address. Set up
the connected unit to use a static IP address and type in this IP address under Static IP
address.
If Automatic Context Activation (ACA) is enabled, the connection is established
automatically. Only the unit with the configured static IP address can use this connection.
3. Click Save.
Note
You can only start and stop a dedicated static IP connection by enabling and
disabling ACA under Parameters or using SMS commands.