Installation Manual
Table Of Contents
- Safety summary
- About this manual
- Introduction to EXPLORER 323
- To install the system
- To get started
- Before you start
- To switch on the EXPLORER 323
- To connect to the LAN interface
- To connect your WLAN-enabled device
- The EXPLORER Connect app
- To access the web interface
- To enter the SIM PIN for the terminal
- To register with the BGAN network
- Mounting calibration
- To start and stop data connections
- To make phone calls over BGAN
- To use the EXPLORER 323
- Configuration with web interface
- The web interface
- To control data connections from web interface
- To set up your data connection packages
- Multiple data connections
- Status information
- The Control panel
- To use the logs
- Terminal settings
- To set up the interfaces
- To manage VoIP phones or smartphones (Not M2M)
- Advanced LAN
- To manage connected devices (Traffic control)
- To set up tracking and location reporting
- Support features
- Advanced settings
- Passwords
- To set up user permissions
- To restore factory settings
- SIM PIN for BGAN
- To save or load a configuration
- Connection watchdog (Link monitoring)
- Terminal watchdog
- Data limits
- Call charges
- Remote management
- Remote control of tracking
- Power save
- To configure data connection types and filters
- Help desk
- Reset button
- Security
- To enter the SIM PIN in the web interface
- Maintenance and troubleshooting
- Specifications
- Command reference
- Conformity
- Glossary
- Index
Appendix B: Command reference
98-169085-B Configuration examples 137
To set up power save functions with AT commands
For details on how to use AT commands see To access the terminal using AT commands on
page 33.
You can set up the following power save functions with AT commands:
• Remote on/off
• Idle time and Daily wake-up
Remote on/off
With the AT command AT_ITREMONOFF you can set up
• Enable or disable the Remote on/off function
• Shut down delay after the Power control pin is deactivated
• Daily awake period (time of day and duration)
• Polarity of the Power control pin (active high or low)
Set up the Remote on/off function as follows:
1. Type in the AT command:
AT_ITREMONOFF=<active mode>,<power down delay>,<awake time of day>,<awake
duration>,<polarity>
Example: AT_ITREMONOFF=1,3,60,10,HIGH
In the example above, Remote on/off is activated (1) with 3 minutes shut down delay (3),
awake time of day 60 minutes after midnight (60), 10 minutes duration of awake time (10)
and Power control pin active high (HIGH).
Important
Before configuring the remote on/off function, connect the Power control pin as
described in To connect Ignition on page 12.
Note
If you set Awake time of day to 0, the daily awake period is disabled.
Note
Changing <active mode> from 1 to 0 will change the power mode from Remote
on/off to Always on.
Changing <active mode> from 0 to 1 will change the power mode to Remote on/off.