Appendix B: Command reference
98-169085-B SMS remote commands 124
SMS reject responses
Reject Response SMS Possible Cause
ACT/DEACT PARM PROBLEM The <IP addr> provided for an ACTIVATE or
DEACTIVATE command is incorrect (for
ACTIVATE, it must be in same subnet as the
EXPLORER 323 IP and not be the
EXPLORER 323 IP; for DEACTIVATE, it must
exist as a local or global IP address in the
existing PDP table).
ATCO ERROR Unable to send AT command to ATC handler.
COMMAND NOT SUPPORTED Attempt to use an SMS command not
supported by the EXPLORER 323.
ERROR: TERMINAL BUSY An ACTIVATE or DEACTIVATE command is
in progress.
INVALID RESTART REQUEST Attempt to perform restart before
EXPLORER 323 has been running for at least
15 minutes.
INVALID WATCHDOG PING ADDRESS Entered Ping address is out of range (0.0.0.0
– 255.255.255.254).
INVALID WATCHDOG PING FREQUENCY Requested Ping Frequency is less than the
minimum (5 minutes).
INVALID WATCHDOG REQUEST "Ping required" or "wdog enabled" fields
incorrect in remote SMS message, or
watchdog request other than "get"
attempted.
WRONG CONNECTION TYPE(NO DHCP TE) No DHCP TEs connected to the Remote Unit.
WRONG CONNECTION TYPE(NO STATIC TE) No Static TEs added in Terminal settings.
WRONG CONNECTION TYPE(NO TEs) No TEs are connected to the Remote Unit.
WRONG PASSWORD Authentication Failure.
WRONG QOS Invalid QoS Requested (only a QoS of 1 is
valid).