User's Manual

Table Of Contents
PRODUCTPREVIEW
15
CC2650MOD
www.ti.com
SWRS187 AUGUST 2016
Submit Documentation Feedback
Product Folder Links: CC2650MOD
SpecificationsCopyright © 2016, Texas Instruments Incorporated
(1) Automatically compensated when using supplied driver libraries.
5.18 Temperature Sensor
T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise noted
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Resolution 4 °C
Range –40 85 °C
Accuracy ±5 °C
Supply voltage coefficient
(1)
3.2 °C/V
5.19 Battery Monitor
T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise noted
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Resolution 50 mV
Range 1.8 3.8 V
Accuracy 13 mV
(1) Additionally the bias module needs to be enabled when running in standby mode.
5.20 Continuous Time Comparator
T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise noted
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Input voltage range 0 V
DDS
V
External reference voltage 0 V
DDS
V
Internal reference voltage DCOUPL as reference 1.27 V
Offset 3 mV
Hysteresis <2 mV
Decision time Step from –10 mV to +10 mV 0.72 µs
Current consumption when enabled
(1)
8.6 µA
5.21 Low-Power Clocked Comparator
T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise noted
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Input voltage range 0 V
DDS
V
Clock frequency 32 kHz
Internal reference voltage, VDDS / 2 1.49 1.51 V
Internal reference voltage, VDDS / 3 1.01 1.03 V
Internal reference voltage, VDDS / 4 0.78 0.79 V
Internal reference voltage, DCOUPL / 1 1.25 1.28 V
Internal reference voltage, DCOUPL / 2 0.63 0.65 V
Internal reference voltage, DCOUPL / 3 0.42 0.44 V
Internal reference voltage, DCOUPL / 4 0.33 0.34 V
Offset <2 mV
Hysteresis <5 mV
Decision time Step from –50 mV to +50 mV <1 clock-cycle
Current consumption when enabled 362 nA