CONNECTOR PINOUT DSUB-26HD ISO 22900-1
1 Manuf. Discretionary diagnostic line 14 CAN L
2 +J1850 15 L-Line
3 Manuf. Discretionary diagnostic line 16 Unswitched battery voltage
4 Power ground 17 Ext. Adapter ID0
5 Signal Ground 18 Ext. Adapter ID1
6 CAN H 19 SPI OUT
7 K-Line 20 SPI IN
8 Manuf. Discretionary diagnostic line 21 SPI CLK
9 Manuf. Discretionary diagnostic line 22 SPI EN
10 -J1850 23 +5V OUT
11 Manuf. Discretionary diagnostic line 24 Switched battery voltage
12 Manuf. Discretionary diagnostic line 25 reserved
13 Manuf. Discretionary diagnostic line 26 Power ground for Ext. Adapter
21