Installation Guide

Tetra
®
EdgeLine Cuttable Light Bar Installation Guide
Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly
disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
If you have any questions about these instructions or your specic application, please contact support at tetra.support@gecurrent.com.
This product is intended solely for sign use only. Not intended for general lighting applications.
Conforms to the following standards: IP66. Acceptable for use in dry and damp locations.
The suitability of rain enclosure shall be determined if intended for wet location.
*GELP24-60U-GL minimum load = 2 bars / 7 ft. 10-3/4 in. (2.41 m)
**GELP24-60U-GL minimum load = 5 bars / 5 ft. (1.52 m)
† Minimum load = 2 bars / 7 ft. 11 in. (2.41 m)
†† Minimum load = 8 bars / 8 ft. (3.05 m)
Maximum Loading per 24 VDC Class 2 Power Supply
Power Supply
GELW4871-1, GELW4865-1,
GELW4850-1, GELW4841-1,
GELW4832-1, GELW4850-1WH GELW1265-1
Rating (per Light Bar) 24V, 696mA, 16.7W 24V, 175mA, 4.2W
25W Power Supply
Load shall not exceed 1.04A
1 bars / 3 ft. 11-3/8 in. (1.20 m) 5 bars / 5 ft. (1.53 m)
60W Power Supply
Load shall not exceed 2.5A
3 bars / 11.8438 ft. 10-1/8 in. (3.61 m)* 13 bars / 13 ft. (3.96 m)**
80W Power Supply
Load shall not exceed 3.3A
4 bars / 15 ft. 9-1/2 in. (4.81 m) 16 bars / 16 ft. (4.88 m)
100W Power Supply
Load shall not exceed 4.0A
5 bars / 19 ft. 9 in. (6.02 m)† 20 bars / 20 ft. (6.10 m)††
200W Power Supply
Load shall not exceed 4.0A
per each (of 2) output channels
5 bars / 19 ft. 9 in. (6.02 m) per bank
10 bars / 39 ft. 6 in. (12.04 m) per PS
20 bars / 20 ft. (6.10 m) per bank
40 bars / 40 ft.
(12.20 m) per PS
300W Power Supply
Load shall not exceed 4A
per each (of 3) output channels
5 bars / 19 ft. 9 in. (6.02 m) per bank
15 bars / 59 ft. 3 in. (18.06 m) per PS
20 bars / 20 ft. (6.10 m) per bank
60 bars / 60 ft. (18.30 m) per PS
Maximum Light Bars in Series connection (S) 3 bars / 11 ft. 10-1/8 in. (3.61 m) 11 bars / 11 ft. (3.35 m)
Parallel Wiring Option
Maximum Light Bars in Series connection (S)
L N
+
-
+
-
LED Controlgear
(Driver)
DC 24V
- +
Light Bar
gecurrent.com/tetra