User Manual
6 Using the product
58
Pos: 96 /TD/Produkt ver wenden/testo 320/tes to 320 Lecksuche @ 11\mod_13 27411894898_79.doc x @ 105286 @ 155 @ 1
6.2.16. Leak detection
This function is not available when the Spain country version is
selected.
During gas leak detection, no measurement is carried out, but gas
detection is performed.
✓ A gas leak probe (0632 3330) must be connected.
You must also refer to the documentation that comes with
the gas leak probe.
Call up function:
> [ ] → Measurement options → [OK] → Gas leak detection
→ [OK].
Carrying out detection:
> Set the gas type to be detected and perform gas leak testing by
following the instructions described in the documentation of the
gas leak probe.
1. Start detection: [ ].
- The gas concentration is displayed, and if it exceeds the limit,
an alarm signal will sound.
Options:
> [Options] → Save: the readings are saved in a record.
> [Options] → Alarm limit: (this function is not available during a
measurement) Adjusting alarm limits.
> [Options] → Alarm signal: (this function is not available during
a measurement) Disable/enable alarm signal.
> [Options] → Zeroing probe: perform zeroing.
> [Options] → Sensor detection: newly inserted sensor is
detected.
2. End detection: [ ].
Pos: 97 /TD/Produkt ver wenden/testo 330/tes to 330 Überschrif t Daten übertragen @ 6\mod_12792 58550805_79.doc x @ 66583 @ 1 @ 1