User Manual

6 Using the product
55
Car
rying out the measurement:
1. Start measurement: [ ].
- The measured value is displayed.
2. End measurement: [ ].
Options:
> [Options] Clipboard: data is saved to the clipboard.
> [Options] Delete clipboard: any data saved to the clipboard
is deleted.
> [Options] Save: the measured values are saved in a record.
Pos: 92 /TD/Produkt ver wenden/testo 320/tes to 320_Gasdurchsatz @ 12\ mod_1337860730512 _79.docx @ 124622 @ 355 @ 1
6.2.12. Gas flow rate
The function is only available if the chosen fuel is a gas.
Call up function:
> [ ] Measurement options [OK] Flowrate [OK].
Carrying out the measurement:
1. Make a note of the gas meter value.
2. Start measurement: [ ].
3. When the adjusted gas flow is reached: [ ].
- The calculated gas flow rate and the gas burner capacity (in
kW) are displayed.
Options:
> [Options] Clipboard: data is saved to the clipboard.
> [Options] Delete clipboard: any data saved to the clipboard
is deleted.
> [Options] Save: the measured values are saved in a record.
> [Options] Enter Gas Flow: set the gas flow value.
> [Options] Enter heating value: heating value can be set.
> [Options] Units setting: the unit for gas flow, heating value,
duration and GasPgr can be changed.
Pos: 93 /TD/Produkt ver wenden/testo 330/tes to 330 Öldurchsatz @ 6\mod_12 79183991201_79.doc x @ 66323 @ 355 @ 1
6.2.13. Oil flow
The function is only available if the chosen fuel is an oil.
Calling up the function:
> [ ] Measurements [OK] Oil Flow [OK].