Datasheet

56
testo Saveris™ Accessories: External temperature probes
Temperature/Humidity
Meas. range AccuracyIllustrationPlug-in probes Part no.t99
125 mm
Ø 4 mm
15 mm
Ø 3 mm
Robust, Pt100 stainless steel food probe (IP65)
0609 2272
-50 to +400 °C
Class A (-50 to +300 °C),
Class B (remaining range)
Conn.: Fixed cable
10 s
114 mm
Ø 5 mm
50 mm
Ø 3.7 mm
Robust, waterproof Pt100 immersion/penetration
probe
0609 1273
-50 to +400 °C
Class A (-50 to +300 °C),
Class B (remaining range)
Conn.: Fixed cable
0554 0213
12 s
Meas. range AccuracyIllustrationPlug-in probes Part no.t99
40 mm
Ø 6 mm
Stationary probe with stainless steel sleeve, TC Type
K
0628 7533
-50 to +205 °C
Class 2*
Conn.: Fixed cable 1.9 m
20 s
115 mm
Ø 4 mm
Robust air probe, T/C Type K
0602 1793
-60 to +400 °C
Class 2*
Conn.: Fixed cable 1.2 m
25 s
35 mm
Ø 20 mm
Magnetic probe, adhesive force approx. 20 N, with
magnets, for measurements on metal surfaces, TC
Type K
0602 4792
-50 to +170 °C
Class 2*
Conn.: Fixed cable
150 s
75 mm
Ø 21 mm
Magnetic probe, adhesive force approx. 10 N, with
magnets, for higher temp., for measurements on
metal surfaces, TC Type K
0602 4892
-50 to +400 °C
Class 2*
Conn.: Fixed cable 1.6 m
Pipe wrap probe for pipe diameter 5 to 65 mm, with
exchangeable measuring head. Meas. range short-
term to +280°C, TC Type K
0602 4592
-60 to +130 °C
Class 2*
Conn.: Fixed cable 1.2 m
5 s
395 mm
20 mm
Pipe wrap probe with Velcro strip, for temperature
measurement on pipes with diameter up to max. 120
mm, Tmax +120°C, TC Type K
0628 0020
-50 to +120 °C
Class 1*
Conn.: Fixed cable 1.5 m
90 s
800 mm
Ø 1.5 mm
1500 mm
Ø 1.5 mm
1500 mm
Ø 1.5 mm
Thermocouple with TC adapter, flexible, 800mm
long, fibre glass, TC Type K
0602 0644
-50 to +400 °C
Class 2*
5 s
Thermocouple with TC adapter, flexible, 1500mm
long, fibre glass, TC Type K
0602 0645
-50 to +400 °C
Class 2*
5 s
Thermocouple with TC adapter, flexible, 1500mm
long, PTFE, TC Type K
0602 0646
-50 to +250 °C
Class 2*
5 s
500 mm
Ø 1.5 mm
Immersion tip, flexible, TC Type K
0602 5792
-200 to +1000 °C
Class 1*
5 s
1000 mm
Ø 3 mm
Immersion measurement tip, flexible, for
measurements in air/exhaust gases (not suitable for
measurements in smelters), TC Type K
0602 5693
-200 to +1300 °C
Class 1*
4 s
Meas. range AccuracyIllustrationPlug-in probes Part no.t99
35 mm
Ø 3 mm
Stub probe, IP 54
0628 7510
-20 to +70 °C
±0.2 °C (-20 to +40 °C)
±0.4 °C (+40.1 to +70 °C)
15 s
40 mm
Ø 6 mm
Stationary probe with aluminium sleeve, IP 65
0628 7503*
-30 to +90 °C
±0.2 °C (0 to +70 °C)
±0.5 °C (remaining range)
Conn.: Fixed cable 2.4 m
190 s
40 mm
Ø 3 mm Ø 3 mm
Accurate imm./pen. probe, 6m cable, IP 67
0610 1725*
-35 to +80 °C
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
Conn.: Fixed cable 6 m
5 s
40 mm
Ø 3 mm Ø 3 mm
Accurate immersion/penetration probe, cable: 1.5 m
long, IP 67
0628 0006*
-35 to +80 °C
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (-35 to -25.1 °C)
±0.4 °C (+75 to +80 °C)
Conn.: Fixed cable 1.5 m
5 s
Wall surface temperature probe, e.g. to prove
damage in building material
0628 7507
-50 to +80 °C
±0.2 °C (0 to +70 °C)
Conn.: Fixed cable 3 m
20 s
125 mm
Ø 4 mm
15 mm
Ø 3 mm
Stainless steel NTC food probe (IP65) with PUR
cable
0613 2211*
-50 to +150 °C
2)
±0.5% of mv (+100 to +150 °C)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
Conn.: Fixed cable 1.6 m
8 s
115 mm
Ø 5 mm
50 mm
Ø 4 mm
Waterproof NTC immersion/penetration probe
0613 1212
-50 to +150 °C
±0.5% of mv (+100 to +150 °C)
±0.2 °C (-25 to +74.9 °C)
±0.4 °C (remaining range)
Conn.: Fixed cable 1.2 m
10 s
300 mm
30 mm
Pipe wrap probe with Velcro for pipe diameter to
max. 75 mm, Tmax. +75°C, NTC
0613 4611
-50 to +70 °C
±0.2 °C (-25 to +70 °C)
±0.4 °C (-50 to -25.1 °C)
Conn.: Fixed cable 1.5 m
Pt100
TC
NTC
Connection cable for unlimited Pt100 stationary probes with screw terminals (4-wire technology), max. cable length: 20 m
*According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
* Probe tested to EN 12830 for suitability in the transport and storage sectors
2) Long-term meas. range +125°C, short-term +150°C (2 minutes)
The specified accuracy class of the Saveris radio and Ethernet probe is
achieved using these external probes.
Meas. range AccuracyIllustrationPlug-in probes Part no.
Humidity / Temperature Probe 12mm
0572 6172
-20 to +70 °C,
0 to +100 %RH
±0,3 °C, ±2 %RH
(2 to 98 %RH)
%RH
Humidity / Temperature Probe 4 mm
0572 6174
0 to +40 °C, 0 to
+100 %RH
±0,3 °C, ±2 %RH
(2 to 98 %RH)
Ø 12 mm
Ø 4 mm