Datasheet

33
Order no.
IAQ probe for the evaluation of
indoor air quality, CO
2
, humidity,
temperature and absolute pressure
measurement, incl. desktop tripod
Vane measuring probe, 100mm
diameter, for measuring with funnel
set 0563 4170
Thermal flow probe with integrated
temperature and humidity
measurement, Ø 12mm, with
telescope (max. 745mm)
testovent 417, funnel set
comprising funnel for disc valves (Ø
200mm) and funnel for fans (330 ×
330mm) for supply and exhaust air
Volumetric flow rectifier testovent 417
Volumetric flow rectifier testovent 417 comprising the testovent 417 funnel set and volumetric flow rectifier
testovent 417
Vane measuring probe, 16mm
diameter, with telescope of
max. 890mm, e.g. for duct
measurement, can be used from
0to +60°C
Vane measuring probe, 60mm
diameter, with telescope of max.
910mm, e.g. for duct outlet
measurement, can be used from
0to +60°C
Hot wire probe form/s and°C,
Ø7.5mm probe head, incl.
telescope (max. 820mm)
0 to +50°C
0 to +100% RH
0 to
+10000ppm
CO
2
+600 to
+1150hPa
+0.3 to +20m/s
0 to +50°C
-20 to +70°C
0 to +100% RH
0 to +20m/s
+0.6 to +40m/s
Operating
temperature
0 to +60°C
+0.25 to
+20m/s
Operating
temperature
0 to +60°C
0 to +20m/s
-20 to +70°C
± 0.3°C
±2% RH (+2 to +98% RH)
±(75ppm CO
2
±3% of m.v.)
(0 to +5000ppm CO
2
)
±(150ppm CO
2
±5% of m.v.)
(+5001 to +10000ppm CO
2
)
± 10hPa
±(0.1m/s +1.5% of m.v.)
± 0.5°C
± 0.3°C
±2% RH (+2 to +98% RH)
±(0.03m/s +4% of m.v.)
±(0.2m/s +1.5% of m.v.)
±(0.1m/s +1.5% of m.v.)
±(0.03m/s +5% of m.v.)
±0.3°C (-20 to +70°C)
0632 1535
0635 9435
0635 1535
0563 4170
0554 4172
0554 4173
0635 9535
0635 9335
0635 1025
Probe
Comfort probe for degree of
turbulence measurement with
telescope (max. 820mm) and
tripod, fulfils requirements of
EN13779
Humidity/temperature probes
Lux probe; probe for measuring
luminous flux
Temperature probe for U-value
determination, threefold sensor for
recording wall temperature, incl.
modelling clay
0 to +50°C
0 to +5m/s
-20 to +70°C
0 to +100% RH
0 to 100,000
Lux
0 to 300Hz
-20 to +70°C
± 0.3°C
±(0.03m/s +4% of m.v.)
± 0.3°C
±2% RH (+2 to +98% RH)
Accuracy as per DIN 13032-1:
f1 = 6% = V(Lambda)
adjustment
f2 = 5% = cos-like weighting
Class C
Class 1
1)
U-value: ±0.1°C ±2% of m.v. *
0614 1635
0628 0109
0636 9735
0635 0545
max. 820mm
Ø 12mm
Note: To determine the U-value an additional probe is required
to record the ambient temperature, e.g. 0602 1793 or 0613
1001/0613 1002.
* for use with NTC or humidity radio probes for measuring
ambient temperature and 20 K difference in air inside/outside
Dimensions
Probe shaft/probe shaft tip
Measuring
range
Accuracy
More products and accessories can be found at testo.com
Multi-function testo 435