INSTRUCTION MANUAL TT-AF 1200 Active Oscilloscope FET-Probe 1,2 GHz / 10:1
1. Safety Terms and Symbols These probe is in compliance with EN61010-031 CAT I, Pollution Degree 2 Terms appear in this manual: ___________________________________________________ WARNING. Warning statements identify conditions or practice that could result in injury or loss life. ___________________________________________________ CAUTION. Caution statements identify conditions or practice that could result in damage to this product or other property.
2. General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this probe or any products that connected to it. Observe Maximum Working Voltage To avoid any injury, do not use the probe under the condition that the voltage between either input head or earth is above ± 40V (DC + peak AC). Must be Grounded This probe is grounded with the shell of BNC connector, through the grounding conductor of the power cord of the measurement instrument.
3. Description With high bandwidth, this active 10:1 probe is ideal for timing analysis or troubleshooting of high speed logic and for design verification of disk drive, as well as for wireless and data communication design. 4. Installation a. Simply plug-in the BNC output connector to the vertical input of an oscilloscope or other measurement instrument with 50Ohm input resistance. The instrument must have a ground reference. b.
5. Appearance The active probe looks as follows. c. d. e. a. b. a. Input Pins the input pins of the active probe can be connected directly to the circuit under test or connected to the accessories that come with the probe. b. Output cable the BNC output connector connected to the oscilloscope c. Power unit power requirements - Mains adapter with 5VDC/200mA or 9VDC/150mA - 9V battery - optional power leads (USB, Probus® or Lemo®) e.
6. Inspection Procedure a. Connect the BNC output connector to the vertical input of a proper grounded oscilloscope with 50Ohm input resistance. b. Turn on the probe by using the switch on the power unit. c. Set the oscilloscope input coupling to DC and to 0.5V/div. Center the trace on the display. d. Connect the input pins of the probe to a function generator and select a square-wave output of 10V amplitude and 100kHz frequency. e.
10. Accessories Type OrderNo.
11.
12. Derating Curve The derating curve of the absolute maximum input voltage in common mode is shown as follows. 13. Warranty TESTEC warrants its probes for normal use and operation within specification for a period of one (1) year from the date of shipment (accessories not included). In exercising its warranty, TESTEC, at its option, will either repair or replace any assembly returned within the warranty period.
14. General © 2017 Testec – All rights reserved. All trademarks are property of their respective manufacturers. TESTEC is a trademark of TESTEC Elektronik GmbH. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice. For product information, sales, service and technical support: TESTEC Elektronik GmbH Manufacturer of Probes and Accessories Fritz-Klatte-Str.