User manual
Operation
Testavit
®
Schuki
®
1 LCD 25
DEUTSCH
ENGLISH
Measurement category IV:
Measurement category IV is applicable to test and measuring
circuits connected at the source of the building’s low-voltage
mains installation. Typical short-circuit current is >> 50kA.
Read the instruction before use. If the equipment is used in a
manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
All parts of the device and its accessories are not allowed to be
changed or replaced, other than authorized by the manufacturer
or his agent.
For cleaning the unit, use a dry cloth.
Technical data
Voltage range 230 V AC, 50 Hz
Power supply by test object, max. 3 mA
FI/RCD Test 30 mA at 230 V AC
Degree of protection IP 40
Over-voltage category CAT II 300 V
Temperature range 0° ~ +50°C
Testing standard IEC/EN 61010-1
(DIN VDE 0411)