Manual
Technical data
16 Testboy
®
TB 30
Replacing the battery
If the standby LED (4) and the LED (6) in the tip of the receiver (contact-free voltage display)
flash simultaneously, the battery voltage is in a critical state.
If the battery voltage of the receiver is too low, the standby LED (4) will not illuminate.
In both cases, replace the 9 V block battery.
To this end, open the battery compartment (5) by pulling down the cover (see arrow symbol on
the cover).
Technical data
Voltage range
210 - 250 V AC
Contact-free voltage test
≥ 110 V AC
Frequency range
50 Hz
Power supply
9 V Block (6LR61)
Operating temperature
5 °C ~ 40 °C
41 °F ~ 104 °F
Storage temperature
-20 °C ~ 60 °C
4 °F ~ 140 °F
Dimensions
192 x 54 x 37 mm (receiver)
95 x 52 x 35 mm (transmitter)
Weight
266 g inc. battery